A fresh-air handling unit with built-in heat recovery: it brings 100% outdoor air into the building while reclaiming energy from the exhaust air, so fresh air no longer drives up your cooling load — from offices to pharmaceutical plants. From compact ceiling-hung units to large modular systems — built on FRIMEC's founding belief that science can make a better world.
A built-in heat exchanger pre-cools incoming fresh air with outgoing exhaust air.
Learn more → 02Mechanical supply and exhaust keep indoor air fresh without wasting conditioned energy.
Learn more → 03Compact FAH-J units up to 10,500 m³/h and modular FCAH systems up to 50,000 m³/h.
Learn more →In summer the exchanger transfers heat from incoming fresh air to the outgoing exhaust air, pre-cooling the fresh air; in winter it works the other way round.
Dedicated supply and exhaust fans deliver a balanced flow of 100% outdoor air, with a flexible outlet layout that is easy to design and install.
Choose chilled-water and hot-water coils to suit the project, or a coil-free fresh air ventilator version.
A honeycomb wheel of coated aluminium foil stores and releases both heat and moisture as it turns between the fresh-air and exhaust streams.
A corrugated aluminium-fin core transfers heat without any heat medium, power source or moving part.
An ethylene-glycol circuit carries energy between separate fresh-air and exhaust units, so the two air streams never meet.
FRIMEC supplies the control cabinet that matches the site power grid and the building management needs.
Wherever a building must bring in large volumes of fresh air, the FAH-J range removes most of the energy penalty that comes with it.
Production areas that run on large volumes of fresh air recover most of that energy; plate and heat-medium recovery keep fresh and exhaust air fully separated against cross-contamination.
Modular FCAH units up to 50,000 m³/h handle the high fresh-air volume of crowded public spaces.
Continuous fresh air for occupants.
Fresh air for rooms and corridors.
Heat-medium recovery keeps air streams fully apart.
High-occupancy classrooms and lecture halls.
Ballrooms, theatres and conference rooms.
Ventilation for production areas.
Smaller chillers, cooling towers, pumps and pipework often offset the extra cost of the unit.
50 – 200 mm wet-film section, up to 64 kg/h humidifying capacity.
Choose total-heat recovery for moisture control or sensible-heat for simpler duty.
Fresh air can bypass the recovery core when outdoor conditions are already favourable.
Supply and exhaust fan positions selectable to protect fresh-air quality.
Few moving parts; after the first three months, inspection about once a year.
| Series | FRIMEC FAH-J Heat Recovery AHU · FCAH Modular Heat Recovery AHU |
|---|---|
| Airflow | FAH-J 1,000 – 10,500 m³/h · FCAH 1,400 – 50,000 m³/h |
| Heat recovery | Built-in total / sensible heat exchanger (FAH-J) · Runner · Plate · Heat medium (FCAH) |
| Recovery efficiency | FAH-J: temperature > 70%, enthalpy > 60% · Runner: total up to 80% · Plate: 72% · Heat medium: 50% |
| Cooling capacity | FAH-J 11.1 – 162.6 kW (2 / 4-row coil) · FCAH 20 – 705 kW |
| Unit type | FAH-J ceiling-hung / horizontal · FCAH ceiling-hung / horizontal / vertical |
| External static pressure | FAH-J supply 40 – 160 Pa · FCAH ≥ 300 Pa |
| Power supply | 380 V |
| Sound level | FAH-J 53 – 66 dB(A) |
| Casing (FCAH) | 25 / 35 / 50 mm wall thickness |
| Control options | Direct, star-delta, VFD or soft starter · Local, remote and BA control · Interlocks |
| Humidifier (optional) | Wet film, 50 / 100 / 150 / 200 mm |
Cooling rated at fresh air 35 °C DB / 28 °C WB, return air 27 °C DB / 19.5 °C WB, chilled water 7 / 12 °C; heating with hot water 60 / 50 °C. Specifications are subject to change without prior notice.